Sign In | Join Free | My himfr.com
Home > Flammability Testing Equipment >

IEC60695-11-5 Needle Flame Tester Flammability Testing Equipment

HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap IEC60695-11-5 Needle Flame Tester Flammability Testing Equipment from wholesalers
     
    Buy cheap IEC60695-11-5 Needle Flame Tester Flammability Testing Equipment from wholesalers
    • Buy cheap IEC60695-11-5 Needle Flame Tester Flammability Testing Equipment from wholesalers
    • Buy cheap IEC60695-11-5 Needle Flame Tester Flammability Testing Equipment from wholesalers
    • Buy cheap IEC60695-11-5 Needle Flame Tester Flammability Testing Equipment from wholesalers
    • Buy cheap IEC60695-11-5 Needle Flame Tester Flammability Testing Equipment from wholesalers

    IEC60695-11-5 Needle Flame Tester Flammability Testing Equipment

    Ask Lasest Price
    Brand Name : HeJin
    Model Number : NF-1
    Certification : calibration certificate (cost additional)
    Price : Negotiatable
    Payment Terms : L/C, T/T
    Supply Ability : 10 set /month
    Delivery Time : 30 days
    • Product Details
    • Company Profile

    IEC60695-11-5 Needle Flame Tester Flammability Testing Equipment

    IEC60695-11-5 Flammability Testing Equipment Needle-Flame Tester With Electrical Control And Button Operation


    Standard:

    IEC 60695-11-5 Fire hazard testing – Part 11 -5: Test flames – Needle-flame test method – Apparatus, confirmatory test arrangement and guidance.


    Description of the test apparatus:

    • Burner:

    The burner to produce the test flame shall consist of a tube at least 35 mm long with a bore of 0.5 mm ± 0.1 mm and an outer diameter not exceeding 0.9 mm.

    The burner is supplied with butane or propane gas having a purity of at least 95 %. There shall be no air admitted to the burner tube.

    • Flame:

    With the axis of the burner in the vertical position, the gas supply is adjusted so that the length of the flame is 1 2 mm ± 1 mm, when viewed in subdued light against a dark background (see Figure 1 a). The flame shall be confirmed using the apparatus and procedure detailed in Annex A. The test time for the temperature to increase from 1 00 °C ± 5 °C to 700 °C ± 3 °C shall be 23.5 s ± 1.0 s.

    • Laboratory fumehood/chamber:

    The laboratory fumehood/chamber shall have an inside volume of at least 0.5 m3. The chamber shall provide a draught-free environment, whilst allowing normal thermal circulation of air past the test specimen. The chamber shall permit observation of the test in progress. The inside surfaces of the walls shall be of a dark colour.

    For safety and convenience, it is desirable that this enclosure (which can be completely closed) be fitted with an extraction device, such as an exhaust fan, to remove products of combustion, which may be toxic. The extraction device shall be turned off during the test and turned on immediately after the timing measurements have been made. A positive closing damper may be needed.


    Parameters:

    ParametersModelNF-1NF-2(Touch screen)
    Working voltage220V/50Hz220V/50Hz
    Control operation modeElectrical control, button operationPLC control, 7 inch color touch screen operation, with infrared remote control
    CombustorInner boreφ0.5mm ± 0.1mm , OD ≤φ0.9mm , L ≥ 35mm, stainless steel
    Gas categoryButane or propane gas having a purity of at least 95% ( can use the bottled lighter gas)
    Height of the flame12±1mm adjustable (with flame height gauge)
    Flame warming requirementFrom 100°±5°C to 700°±3°C,time for standard values within 23.5S±1S
    Combustion angleTilt 45°( testing ) or vertical ( when adjust the height of the flame)
    TrayA layer of silk paper (12~30g/m³) is covered on the 10mm thick pine board, with a distance of 200±5mm below the test sample
    Timer/sustained combustion0-9999X0.1S
    Temperature measuring distance

    The distance between the top center of the burner and the test sample: 8±1mm

    Temperature calibration

    Temperature measuring copper head: Φ4±0.01mm, weight: 0.58±0.01g

    Temperature thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100°

    Temperature measuring distance:6±0.5mm
    Air volume controlThe flame height can be adjusted by adjusting the flow meter
    Test procedureAutomatic control, independent exhaust
    LightingEquip with lighting in the test chamber, with control
    Test chamber and dimensions>0.5 cube, black yogon background, with exhaust fan, size:1100*550*1200mm, weight:130kg